he RosettaBridge TMS can automatically switch the projection lamp off between shows based on the time gap between shows. Special macros “first show start” and “Last show end” should be added to every playlist.
The first book show each day has “First show start” macro insert
The last show each day has “Last show end” macro inserted
If the gap between shows is less than defined by property feature.booking.automation.firstLastGap then these macros are not inserted during the day.
If the gap between shows is longer that defined by property feature.booking.automation.firstLastGap then the special macros “first show start” and “Last show end” are added to the scheduled playlists.
Consecutive Show Macros
Define the "consecutive shows" macros as lamp on and lamp off at your site under
SERVICE--Macros--Automation settings
Lamp On function macro should be the “First show start” macro and Lamp Off function should be “Last Show End”
Property to Define Minimum Time Gap Between Shows
By default the gap between shows is set to 20 minutes
feature.booking.automation.firstLastGap = 0 20
Special macros


The special macros should be added to every playlist.