TMS Monitoring and Device Control
RosettaBridge Site Monitoring page provides show status information and manual control of auditorium devices.
Several monitor views are available by selecting the monitoring icons on the top right of the screen.
Clicking the Notification icon will display local site notifications on the left side of the screen
Device Control
Clicking the playback status icon for an auditorium accesses basic playback controls
Clicking the Mode icon for an auditorium allows the Player Scheduling Mode to be changed
Clicking Projector lamp status icon access lamp controls
Clicking projector dowser status icon accesses dowser controls
Clicking on any Screen icon will expand full control and status information for the Auditoriums
IDLE
PAUSED
PLAYING and Status is good
ERROR State
Auditorium Control View
Player Scheduling Modes
Scheduling Mode | Description |
Read Only (R) | TMS does not send playlist of schedule data to the player |
Manual (M) | TMS sets player in manual playback mode. TMS will not automatiucally load or start any scheduled shows |
Semi (S) (Load) | TMS loads the scheduled playlist but does not send play command |
Auto TMS (A) | TMS loads a scheduled playlist and sends play commands to start playback base don TMS time |
Auto Player (P) | TMS sends schedule and playlists to player. Sents Player in local scheduler mode. The player scheduler loads and starts each show. This is the recommended mode for normal operation |